Overview
This owner’s handbook covers the B&D Controll-A-Door automatic garage door opener, model MPC-2, for compatible B&D Roll-A-Door installations. It explains everyday operation, manual release during a power failure, memory and transmitter behaviour, installation requirements, travel-limit and sensitivity setup, code programming and installation troubleshooting. The installation sections involve heavy, spring-tensioned door components, so this summary is not a substitute for the complete instructions or competent installation work.
Important safety information
Unlock the Roll-A-Door centre-lift lock before operating the Controll-A-Door. Keep the moving door in view, check that the doorway is clear and confirm the door is fully closed before driving away. The handbook stresses that the unit is not a child’s plaything and must be used carefully by appropriate users.
Do not allow water or other liquids into the motor, wall control or hand transmitter. The drive and wall control must be mounted out of the weather; the unit is not designed for external use. A properly earthed 240 V, three-pin power point is required. If an extension lead is used, the handbook specifies a three-core lead.
The door must operate smoothly by hand. Its maximum starting effort in either direction must not exceed 200 N (20 kg force), and the door should be balanced so opening and closing effort are equal. Door balancing requires control of spring tension and a firmly held axle. The full procedure uses ropes, a large pipe wrench and loosened U-bolts; it should be performed only by people competent to work safely on tensioned garage-door hardware. The handbook specifically recommends experienced door installers for Series 2 installations, and qualified installation or service may be required more generally.
The reversing sensitivity is set during installation to suit the door. If the door encounters an obstruction while closing, it should reverse; an overload while opening can stop the door and trigger a retry or flashing reset indication. After power returns, the first downward “warm-start” movement reconfirms the lower limit, and the manual warns that automatic reversing does not operate during that first down movement. Keep the area clear and follow the original procedure exactly.
Installation/setup overview
Compatibility must be confirmed before work begins. The handbook includes model-specific criteria for Series 1, Security Plus, and Series 2 or 3 Nylofelt doors, including a 2100 mm height limit for the described Series 2 and 3 application. Side-room requirements vary by door series and installation side. For Series 1 and 3 doors, stated recommended side room is 130 mm at the left end or 155 mm at the right, with minimums of 110 mm and 135 mm. Series 2 Wideline requirements range from 175 to 195 mm depending on door width. An already-installed door requires an additional 145 mm clearance to slide the drive unit over the axle.
The installation sequence checks and corrects manual door travel, supports and partly removes the door from its bracket, disengages and slides the drive unit onto the axle, then refits and aligns the door. Reinforcing plates, weight bars and stop components are required in the applications identified by the manual. The curtain must be pinned to both drums using the specified positions and fasteners; the handbook labels this an extremely important security procedure. Power and control cables must be secured well away from moving parts.
The wall control is mounted indoors, protected from weather and within 1.2 m of the drive unit. A rear selector configures left- or right-hand operation, while two front switches select one of four reversing-sensitivity settings according to door type and running effort. The aerial should extend vertically above the case and remain clear of sheet metal, with at least 20 mm spacing if a non-metal block is used.
Travel limits are first set manually with the drive disengaged: lower limit before upper limit. The automatic sequence then confirms the floor and top-stop positions. Because the door can close firmly against the floor and contact its top stops during setup, the complete manual and diagrams are essential.
Operation/programming overview
Use the wall panel’s UP-STOP-DOWN control or press the handheld transmitter for about half a second to open or close the door. An activation while the door is moving down sends it back up; an activation while it is moving up stops it. The next activation then closes it.
For manual use during a power failure, operate the disengagement handle in the direction specified for a left- or right-side installation. When power returns, ensure the drive is re-engaged, activate the unit and allow the door to complete the manual’s memory-confirmation movement. The transmitter code normally remains stored. However, if power is off for more than about three weeks, the backup memory battery may discharge and both travel limits and the code may need to be set again.
The wall control stores the travel limits and transmitter code. Code programming is available only after the limits are set. The transmitter has nine user-set switches with “−”, “0” and “+” positions; switch 1 is inactive on single-channel transmitters. After choosing a personal combination, use CODE SET and press the transmitter for two seconds as directed. Normal operation then uses a half-second press. The supplied transmitter operates at 318 MHz. The courtesy light comes on during operation and switches off after approximately 2½ minutes.
Troubleshooting overview
No wall-control lights usually indicate that the control harness is not fully seated. If the top limit cannot be set, verify the left/right selector and ensure the bottom limit was set first. A door that reverses by itself may be too sensitive, over-tensioned, tight in the guides or ballooning. A door that stops while opening may need better balancing or a less-sensitive setting.
Ballooning can result from a missing weight bar, lintel interference, guide-block damage or dirty guides. The manual says not to use WD-40, CRC, car polish, furniture polish or talc in the guides because absorbed residue increases dirt and friction. A door that closes too tightly or strikes the top stops may have an improperly pinned curtain, incorrect tension or limits needing reset. Poor radio range calls for checking that the aerial is intact, vertical and away from sheet metal. Unresolved door balance, tension, overload, limit or reversing faults should be handled by an experienced installer or service technician.
Full manual note
Refer to the original PDF for diagrams, complete procedures, door-compatibility details, side-room tables, fastener locations, limit and sensitivity sequences, specifications, troubleshooting tables, accessories and warranty terms. Use the original instructions and qualified assistance for any safety-critical installation, balancing, adjustment or repair.