M

ECA DCP-240 Manual

SETTINGS

AUTOMATIC SET UP; Self Learning – the control panel sets the opening and closing time automatically.
This sophisticated control panel has a self-learning system that sets up opening and closing time, automatically. It is a must to run the automatic set up after installing the motor. The automatic set up will set the time in which the gate takes to close fast, and the time it needs to slow down towards the end of closure as well as for the opening operation. Before operating the motor, it is necessary to disconnect the motor from the gate by putting the gateon manual, and checking whether the motor’s rotation is to the right direction of opening and closing of the gate by manually hitting the limit switches to the right and left direction. Check that the limit switches function accordingly to the opening and closing directions.

HOW TO SET THE OPENING AND CLOSING TIME, and THE RAMP UP and SLOW DOWN TIME.

AUTOMATIC SET UP

  1. Remove the “TIMER” jumper in the CP and the PROGRAM LED will turn ON.
  2. Press and release button (I) on the remote control of the unit and the automatic set up will begin.
  3. The gate will open and close twice after which it will stop.
  4. Return the jumper “TIMER” to its place. END OF SET UP.

Now the unit is ready for operation. Press the button on the remote control and the gate will start to open slowly and then fast and slow down towards the end and stop. The ramp-up and ramp-down time are set in the CP automatically and can not be changed.