M

ATA – NeoSlider manual grey v1.01
(warranty pages updated)

Control Board Adjustments

Menu 7. Operating modes

PE input response mode
The PE input can be confi gured to respond in one of three modes:

1. Open and close cycles stop
In this mode all cycles are prevented from being completed or initiated when the PE input is active.

2. Close cycles stop
In this mode the PE input has no effect when opening, but will stop the gate when closing.

3. Reverses close cycles
In this mode the PE input has no effect when opening, but will cause the gate to reverse if activated when closing.

PED input function
The PED input can be confi gured to a SWIPE type input for pedestrian access. This provides full functionality with the PE Triggered Pedestrian Auto-Close function.

Remote code
The controller supports the Remote Code Set feature. This parameter can be used to disable the feature for security or transmitter management reasons.

Activity reports
This parameter enables activity report outputs. Contact Automatic Technology for more details.

Activity report ID
This parameter sets the ID of the controller that is sent with the activity report. Contact Automatic Technology for more details.

Vacation mode
Vacation mode can be turned on or off using this parameter.

Battery/Solar mode
The controller can be instructed to turn off the battery backup facilities so that the control board can be shut down without having to disconnect the battery backup system.

Password protection
The password feature enables all parameters and confi guration settings to be protected unless a password is entered. When this feature is turned on, the user is requested to enter the desired password to be used. The password protection feature has a time-out that expires after 60 seconds of inactivity. Alternatively the user may log out manually by pressing exit when the main screen is displayed.

Open input polarity
The OPN input is normally confi gured for N/O operation. This parameter allows its operation to be changed to N/C