M

B&D RDO-1v3 Manual

System Specifications

Maximum Door Size: 3000mm high 5500mm wide (16.5m2) residential rolling garage door, or 2400mm high wind lock residential rolling garage door.

Door Load:

  • Rated Load: 550N
  • Recommended Load: 200N (20kgs).
  • Ideal Load: 70N (7kgs)

Supply Voltage: 230 – 240 V AC 50Hz
Courtesy Light: LED (Light Emitting Diode) lighting. Light comes on when door starts, turns off approx. 4½ minutes later and can be programmed to operate from a remote control transmitter.
Limit Adjustment: Electronic
Force Control: Electronic – fully automatic. Can be adjusted for environmental reasons.
Transmitter Frequency: 433.47, 433.92, 434.37 MHz
Coding type: Tri-Tranâ„¢
Transmitter battery: CR2032 (3 Volts)
Powerhead Weight: 7.6kg Max.
Door Drum Rotation: 3 Turns
Auxiliary Power Supply: 24-35VDC at 100mA
Rated Load: 550N
Auxiliary Output: Transistor output 35V 100mA. Connected to GND when activated
External Aerial Connection: 2-Pin Screw Connector

Pre-Installation Requirements

Door Operation
The door must be in good operating condition. The maximum effort to move the door up or down, from stationary, should not exceed 200 Newtons (20kg force) at the bottom rail. The recommended force is 70N (7kg) for manual operation.

Lift the door to about halfway. When released, the door should stay in place supported entirely by its springs. Also raise and lower the door to check for any binding or sticking.

The door may need to be serviced to meet these requirements – refer to the door manufacturer’s servicing instructions or contact an authorised dealer.

Unsuitable Door Types
The fitting of an opener to doors with removable mullions is not recommended.

Position
The opener can be installed on either the right hand or left hand side of the door (when viewed from inside the garage). The opener is factory set for right hand side installation.

This opener must be installed in a dry position that is protected from the weather. Moisture or corrosion damage is not covered by the Warranty.

Power Supply
A properly earthed 3 pin single-phase power supply is required.

Side room
The minimum side room required from the edge of the door curtain is 41mm to the inside of the door bracket, and 85mm to the wall (Fig. 01).

The recommended side room from the edge of the door curtain is 95mm to the inside of the door bracket, and 135mm to the wall (Fig. 02).

NOTE: Door Axle Diameter must not exceed 35mm.